SAP aRFC Monitor
Deprecated
This sensor is deprecated. Please use SAP aRFC Monitor V2 instead.
SM58 Monitoring. Monitors status of transactional RFC per client.
General
| Executable | SAP_aRFC_Monitor.exe |
| Connection method | RFC |
| Ports |
|
Default parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
| Host | <ip> | <hostname> | empty | Hostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect. |
| SAPSID | string (3) | XXX | empty | SID of the SAP system |
| SAPInstance | number (2) | 00 - 99 | empty | Instance number of the SAP system |
| SAPClient | number (3) | 000 - 999 | empty | SAP Client (CLNT/MANDT) |
| SAPUsername | string | empty | SAP user |
| SAPPassword | string | empty | Password of the SAP user |
Sensor-specific parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
| Destination |
| * | Name of the RFC destination(s) to be monitored.
|
| MessageState |
| CPICERR,SYSFAIL | Error states which should be counted as errors.
|
| FunctionModule |
| * | Name of the function module(s) to be monitored.
|
Channels
| Channel name | Description | Lookup file |
|---|---|---|
| SM58 today | Displays the number of same-day transactional calls | |
| SM58 Error today | Shows the number of transactional calls with the same number of errors on the same day | |
| SM58 Error last 7 days | Displays the number of transactional calls with errors in the last 7 days | |
| SM58 Error this month | SM58 Error this month Displays the number of incorrect transactional calls per month | |
| SM58 Error all time | Displays the number of all incorrect transactional calls |
Important notes
warning
Please check the channel limits in PRTG if they fit for your alerting.
Troubleshooting
| Error Code | Error Message | Possible Solution |
|---|---|---|
[SCN-056-000] | The following parameters has not been provided: <parameters> Please read the sensor documentation for further information! | Specify the listed parameters in the profile or in the sensor-specific parameters. |
[SCN-056-100] | RFC Connection error: <message> | Check the SAP connection parameters (Host, SAPInstance, SAPSID, SAPClient, SAPUsername, SAPPassword) and that the SAP system is reachable from the PRTG probe. The message from SAP tells you the cause (e.g. wrong password, locked user, missing authorization for RFC). |
Changelog
| Version | Changes |
|---|---|
| 2026.02 | This sensor is deprecated and is replaced by SAP aRFC Monitor V2. |
| 2024.04 | A code part has been corrected which lead to an exception on the 29th of February in a leap year. |
| 2024.01 | The calculation of the week and month timeframe has been corrected |
| 2022.05 | Correction of table read to adapt new complexity restrictions of SAP function module |
| 1.4.0.1 | Rebuild for new signature of AddChannel method |
| 1.4.0.0 | Build for installer 1.4.0 |
| 1.3.6.0 | First stable release |