Skip to main content
Version: 2026.10

SAP Dump Monitor V2

info

This sensor is a replacement for the SAP Dump Monitor which is not working anymore for SAP S/4HANA 2023 FPS01 and above.

Monitoring of System Dumps. Shows how many system dumps in general and unique system dumps have occurred.

General​

ExecutableSAP_Dump_MonitorV2.exe
Connection methodRFC
Ports
  • 33$$
  • 48$$ (SNC) ($$ = Instance number)

Default parameters​

Parameter namePossible valuesDefaultDescription
Host<ip> | <hostname>emptyHostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect.
SAPSIDstring (3) | XXXemptySID of the SAP system
SAPInstancenumber (2) | 00 - 99emptyInstance number of the SAP system
SAPClientnumber (3) | 000 - 999emptySAP Client (CLNT/MANDT)
SAPUsernamestringemptySAP user
SAPPasswordstringemptyPassword of the SAP user

Sensor-specific parameters​

Parameter namePossible valuesDefaultDescription
Minutesnumber (4) | 1 - 1440 (24h)60Last x minutes to check.
IncludeProgramsstring | <PROGRAM1>,<PROGRAM2>,...*

Specifies the programs to filter by. (* can be used as wildcard)

IgnoreProgramsstring | <PROGRAM1>,<PROGRAM2>,...NONE

Specifies the programs that should be ignored. (* can be used as wildcard)
(If a program is listed in the "IncludePrograms" parameter AND in the "IgnorePrograms" parameter, a short dump caused by this program will not be counted.)

Channels​

Channel nameDescriptionLookup file
Short DumpsNumber of short dumps in the system within the last x minutes.
Unique Short DumpsNumber of unique short dumps in the system within the last x minutes.

Important notes​

warning

Please check the channel limits in PRTG if they fit for your alerting.

Troubleshooting​

Error CodeError MessagePossible Solution
[SCN-065-000]The following parameters has not been provided: <parameters> Please read the sensor documentation for further information!Specify the listed parameters in the profile or in the sensor-specific parameters.
[SCN-065-001]Parameter "Minutes" is not a correct integer value!Specify a number between 1 and 1440 in the parameter Minutes.
[SCN-065-002]Parameter "Minutes" cannot be more than 1440 (24h)!Specify a number between 1 and 1440 in the parameter Minutes.
[SCN-065-100]RFC Connection error: <message>Check the SAP connection parameters (Host, SAPInstance, SAPSID, SAPClient, SAPUsername, SAPPassword) and that the SAP system is reachable from the PRTG probe. The message from SAP tells you the cause (e.g. wrong password, locked user, missing authorization for RFC).
[SCN-065-200]Failed to get Dumps with function module <function module>: <message>None of the function modules could read the short dumps. Check that the RFC user is authorized to call the listed function modules (authorization object S_RFC).

Changelog​

VersionChanges
2025.02

Fixed a bug to display a proper error message when the monitoring user has no permission for a function module.

2024.07

The newest versions of SAP BW/4HANA can be checked as well by this sensor This sensor can now also be used for older versions like SAP Netweaver 7.5 and will replace the deprecated SAP Dump Monitor

2024.04First stable release.