Skip to main content
Version: 2026.10

SAP BusinessObjects Monitor (deprecated)

Deprecated

This sensor is deprecated. Please use SAP Business Objects Monitor V2 instead.

Monitors the status of SAP Business Objects

General​

ExecutableSAP BusinessObjects Monitor.exe
Connection methodHTTP
Ports
  • 6405
  • 8480
Lookup files
  • itesys.sapbusinessobjectsmonitor.loginstatus.ovl
  • itesys.sapbusinessobjectsmonitor.serverstatus.ovl

Default parameters​

Parameter namePossible valuesDefaultDescription
Host<ip> | <hostname>emptyHostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect.
OSUsernamestringemptyOperating system user
OSPasswordstringemptyPassword of the operating system user

Sensor-specific parameters​

Parameter namePossible valuesDefaultDescription
AuthMethodsecEnterprise | ldap | sap | windowsADsecEnterpriseAuthentication method
Username<username>BO-webuser
PasswordPassword of <Username>
CMSQueryPortnumber (5) | 1 - 655356405CMS Port
HTTPPortnumber (5) | 1 - 655358480HTTPPort
Protocolhttp | httpshttpHTTP Protocol

Channels​

Channel nameDescriptionLookup file
<server>Status of the Servers
  • Running
  • Server running with errors
  • Server not running

Lookup values​

Values, states and texts defined in the lookup files of this sensor.

Lookup file: itesys.sapbusinessobjectsmonitor.loginstatus.ovl

ValueStateDescription
0OKLogin successful.
1ErrorFailed to load Loginpage.
2ErrorFailed to Login.

Lookup file: itesys.sapbusinessobjectsmonitor.serverstatus.ovl

ValueStateDescription
0OKRunning
1WarningServer running with errors
2ErrorServer not running.

Important notes​

warning

Please check the channel limits in PRTG if they fit for your alerting.

Troubleshooting​

Error CodeError MessagePossible Solution
[SCN-059-000]The following parameters has not been provided: <parameters> Please read the sensor documentation for further information!Specify the listed parameters in the profile or in the sensor-specific parameters.
[SCN-059-300]Unable to determine BO NumberThe sensor could not read the BusinessObjects version. Check the connection parameters and that the BI platform is running.
[SCN-059-301]Unable to determine BI NumberThe sensor could not read the BI version. Check the connection parameters and that the BI platform is running.
[SCN-059-302]Unable to get Logon-Token: <message>The logon to the CMS failed. Check the username, password and authentication method and that the CMS is reachable from the PRTG probe.
[SCN-059-303]Unable to logoff: <message>The logoff from the CMS failed. Check that the CMS is still reachable.
[SCN-059-304]Error: <message>Reading the server status failed. Check the message for details.
[SCN-059-305]Error in listing Servers!The server list could not be read. Check that the user has permission to list the servers.

Changelog​

VersionChanges
2025.02Fixed bug to ensure that the parameter Protocol takes effect
2021.09Added parameter Protocol
1.4.0.2Removed login check
1.4.0.1Rebuild for new signature of AddChannel method
1.4.0.0Build for installer 1.4.0
1.3.6.0First stable release