SAP aRFC Monitor V2
info
This sensor is a replacement for the SAP aRFC Monitor which is not following our principles of monitoring anymore.
Monitors errors of asynchronous RFC based on different filters.
General
| Executable | SAP_aRFC_MonitorV2.exe |
| Connection method | RFC |
| Ports |
|
Default parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
| Host | <ip> | <hostname> | empty | Hostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect. |
| SAPSID | string (3) | XXX | empty | SID of the SAP system |
| SAPInstance | number (2) | 00 - 99 | empty | Instance number of the SAP system |
| SAPClient | number (3) | 000 - 999 | empty | SAP Client (CLNT/MANDT) |
| SAPUsername | string | empty | SAP user |
| SAPPassword | string | empty | Password of the SAP user |
Sensor-specific parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
| Minutes | 1 - 1440 (max. 24h) | 60 | Past minutes to check |
| Destinations | <destination1>[,<!destination2>[,<destination3>,...]] | * (all destinations) | Filter for destinations (* can be used as wildcard, Prefix ! can be used for negative filtering) |
| FunctionModules | <function_module1>[,<function_module2>[,<function_module3>,...]] | * (all function modules) | Filter for function modules (* can be used as wildcard, Prefix ! can be used for negative filtering) |
| Messages | <messages1>[,<messages2>[,<messages3>,...]] | * (all messages) | Filter for messages (* can be used as wildcard, Prefix ! can be used for negative filtering) |
Channels
| Channel name | Description | Lookup file |
|---|---|---|
| Errors | Displays the number of found errors based on the filters. |
Important notes
warning
Please check the channel limits in PRTG if they fit for your alerting.
Troubleshooting
| Error Code | Error Message | Possible Solution |
|---|---|---|
[SCN-105-000] | The following parameters has not been provided: <parameters> Please read the sensor documentation for further information! | Specify the listed parameters in the profile or in the sensor-specific parameters. |
[SCN-105-051] | Parameter "Minutes" is not a correct integer value! | Specify a number between 1 and 1440 in the parameter Minutes. |
[SCN-105-052] | Parameter "Minutes" cannot be more than 1440 (24h)! | Specify a number between 1 and 1440 in the parameter Minutes. |
[SCN-105-100] | RFC Connection error: <message> | Check the SAP connection parameters (Host, SAPInstance, SAPSID, SAPClient, SAPUsername, SAPPassword) and that the SAP system is reachable from the PRTG probe. The message from SAP tells you the cause (e.g. wrong password, locked user, missing authorization for RFC). |
Changelog
| Version | Changes |
|---|---|
| 2026.02 | First stable release |