Skip to main content
Version: 2026.10

SAP SOST Monitor

Monitors outgoing mail and fax messages like they are visible in transaction SOST

General​

ExecutableSAP_SOST_Monitor.exe
Connection methodRFC
Ports
  • 33$$
  • 48$$ (SNC) ($$ = Instance number)

Default parameters​

Parameter namePossible valuesDefaultDescription
Host<ip> | <hostname>emptyHostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect.
SAPSIDstring (3) | XXXemptySID of the SAP system
SAPInstancenumber (2) | 00 - 99emptyInstance number of the SAP system
SAPClientnumber (3) | 000 - 999emptySAP Client (CLNT/MANDT)
SAPUsernamestringemptySAP user
SAPPasswordstringemptyPassword of the SAP user

Sensor-specific parameters​

Parameter namePossible valuesDefaultDescription
Minutesnumber | 1 - n60Last minutes to check.

Channels​

Channel nameDescriptionLookup file
Email errorsNumber of errors when sending emails
Email successfulNumber of successfully sent email messages
Email messages waitingNumber of waiting email messages
FAX errorsNumber of errors during FAX transmission
FAX successfulNumber of successfully sent FAX messages
FAX messages waitingNumber of waiting FAX messages

Important notes​

warning

Please check the channel limits in PRTG if they fit for your alerting.

Troubleshooting​

Error CodeError MessagePossible Solution
[SCN-075-000]The following parameters has not been provided: <parameters> Please read the sensor documentation for further information!Specify the listed parameters in the profile or in the sensor-specific parameters.
[SCN-075-051]Parameter "Minutes" is not a correct integer value!Specify a number between 1 and 1440 in the parameter Minutes.
[SCN-075-052]Parameter "Minutes" cannot be more than 1440 (24h)!Specify a number between 1 and 1440 in the parameter Minutes.
[SCN-075-100]RFC Connection error: <message>Check the SAP connection parameters (Host, SAPInstance, SAPSID, SAPClient, SAPUsername, SAPPassword) and that the SAP system is reachable from the PRTG probe. The message from SAP tells you the cause (e.g. wrong password, locked user, missing authorization for RFC).

Changelog​

VersionChanges
2021.09
  • Introduced parameter Minutes to avoid sensor to keep status Down for a long time if thresholds have been reached
  • Added channels for successfully sent messages
1.4.0.1Rebuild for new signature of AddChannel method
1.4.0.0Build for installer 1.4.0
1.3.6.0First stable release