SAP SOST Monitor
Monitors outgoing mail and fax messages like they are visible in transaction SOST
General
| Executable | SAP_SOST_Monitor.exe |
| Connection method | RFC |
| Ports |
|
Default parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
| Host | <ip> | <hostname> | empty | Hostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect. |
| SAPSID | string (3) | XXX | empty | SID of the SAP system |
| SAPInstance | number (2) | 00 - 99 | empty | Instance number of the SAP system |
| SAPClient | number (3) | 000 - 999 | empty | SAP Client (CLNT/MANDT) |
| SAPUsername | string | empty | SAP user |
| SAPPassword | string | empty | Password of the SAP user |
Sensor-specific parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
| Minutes | number | 1 - n | 60 | Last minutes to check. |
Channels
| Channel name | Description | Lookup file |
|---|---|---|
| Email errors | Number of errors when sending emails | |
| Email successful | Number of successfully sent email messages | |
| Email messages waiting | Number of waiting email messages | |
| FAX errors | Number of errors during FAX transmission | |
| FAX successful | Number of successfully sent FAX messages | |
| FAX messages waiting | Number of waiting FAX messages |
Important notes
warning
Please check the channel limits in PRTG if they fit for your alerting.
Troubleshooting
| Error Code | Error Message | Possible Solution |
|---|---|---|
[SCN-075-000] | The following parameters has not been provided: <parameters> Please read the sensor documentation for further information! | Specify the listed parameters in the profile or in the sensor-specific parameters. |
[SCN-075-051] | Parameter "Minutes" is not a correct integer value! | Specify a number between 1 and 1440 in the parameter Minutes. |
[SCN-075-052] | Parameter "Minutes" cannot be more than 1440 (24h)! | Specify a number between 1 and 1440 in the parameter Minutes. |
[SCN-075-100] | RFC Connection error: <message> | Check the SAP connection parameters (Host, SAPInstance, SAPSID, SAPClient, SAPUsername, SAPPassword) and that the SAP system is reachable from the PRTG probe. The message from SAP tells you the cause (e.g. wrong password, locked user, missing authorization for RFC). |
Changelog
| Version | Changes |
|---|---|
| 2021.09 |
|
| 1.4.0.1 | Rebuild for new signature of AddChannel method |
| 1.4.0.0 | Build for installer 1.4.0 |
| 1.3.6.0 | First stable release |