SAP RFC Ping Monitor
General
Checks if an RFC connection to the system can be established and if the monitoring user is able to login.
| Executable | SAP_RFC_Ping_Monitor.exe |
| Connection method | RFC |
| Ports |
|
Default parameters
| Parameter name | Possible values | Default | Description |
|---|---|---|---|
Host | <ip> | <hostname> | empty | Hostname or IP of the target system. If you use a virtual hostname on your SAP servers, please use also the virtual host to connect. |
SAPSID | string (3) | XXX | empty | SID of the SAP system |
SAPInstance | number (2) | 00 - 99 | empty | Instance number of the SAP system |
SAPClient | number (3) | 000 - 999 | empty | SAP Client (CLNT/MANDT) |
SAPUsername | string | empty | SAP user |
SAPPassword | string | empty | Password of the SAP user |
Channels
| Channel name | Description | Lookup file |
|---|---|---|
| Ping Time | Response time of the RFC ping. |
Important notes
warning
Please check the channel limits in PRTG if they fit for your alerting.
Troubleshooting
| Error Code | Error Message | Possible Solution |
|---|---|---|
[SCN-103-000] | The following parameters has not been provided: <parameters> Please read the sensor documentation for further information! | Specify the listed parameters in the profile or in the sensor-specific parameters. |
[SCN-103-100] | RFC Connection error: <message> | Check the SAP connection parameters (Host, SAPInstance, SAPSID, SAPClient, SAPUsername, SAPPassword) and that the SAP system is reachable from the PRTG probe. The message from SAP tells you the cause (e.g. wrong password, locked user, missing authorization for RFC). |
Changelog
| Version | Changes |
|---|---|
| 2026.02 | First stable release |